Use this guide to identify the documented Dropair Mini6-series connection routes for York air conditioning. Compatibility depends on the exact indoor unit, control interface, adapter hardware, firmware and cable—not the brand name alone.
Source: Mini6 / Mini6S Installation and Service Manual V7.3.2, 15 June 2026, pages 35–38.
Choose the documented connection route
YK-AB
Adapter: Mini6S. Installation condition: York VRF unit with a two-wire wired controller on A/B.
Follow the parallel connection shown in section 4.8.1; the documented two-wire connection is non-polarized.
YK-CN10
Adapter: Mini6. Installation condition: CN10 socket on the indoor PCB.
The manual specifies the CR-CN10-10P cable and removal of the wired controller that occupies that socket.
YK-CN7
Adapter: Mini6. Installation condition: CN7/X940 socket with the described round-screen, four-wire controller arrangement.
Named series include YGFN, YEFN, YKGN, YKFN, YGKN, YGJN, YFGN, YFFN, YAGN, YGGN, YAKN, YEKN, YAJN and YEJN. Use the YK-CN7 cable arrangement shown.
YK-CN6
Adapter: Mini6. Installation condition: CN6 socket with the described five-wire controller arrangement.
The manual names NTH-END-FF-02 and model YE7LD30FC7AA41-G2. Check the equipment label and the exact pictured connector.
YK-SIR
Adapter: Confirm configuration. Installation condition: Section 4.8.5 directs the reader to the universal IR chapter 4.19 (pages 50–51).
This section gives limited selection detail. Request confirmation of the receiver, firmware and any IR accessory before ordering.
Model and installation limits
- CN10, CN7/X940 and CN6 arrangements use different cable pin assignments. Do not swap or repin cables from a text summary.
- The guide’s model and series examples are copied as identifiers from the manual, not a guarantee of support for every regional variant.
The examples above identify the model or interface families explicitly mentioned in this manual. A missing model number is not confirmation of either support or incompatibility. Request a review for your exact installation.
Original installation diagrams
These crops preserve the original diagrams, cable labels and surrounding installation notes. Read them in page order; some solutions continue across two pages. Select an image to inspect its full-resolution labels, and use the linked manual for the complete procedure.




Universal IR reference
For the IR route referenced by this brand section, confirm the correct receiver and firmware. The extended-sender arrangement is for single-air-conditioner control and is not the multi-equipment solution.

Installation workflow
- Check the complete indoor-unit model and control interface, then verify the adapter label, firmware and supplied cable against the chosen solution.
- Test the air conditioner with its original controller before making changes. Record any existing faults.
- A qualified installer must isolate and verify the electrical supply before wiring. Mini6 / Mini6S have a 100–240 VAC input; their thermostat output is 24 VAC. These are not interchangeable connections.
- Follow the exact brand diagram and retain the original controller unless that diagram specifically requires removal. Do not translate one brand’s terminal assignments to another.
- Connect the supported thermostat using the model-specific thermostat diagram and correctly terminated T568B CAT5/CAT6 cable. The RJ45 socket is not Ethernet and must never connect to a router or switch.
- After wiring checks, commission the configured heating/cooling and fan functions supported by the actual equipment. Thermostat models have different terminal definitions and fan-speed capabilities.
Source: Mini6 / Mini6S Installation and Service Manual V7.3.2, 15 June 2026, pages 6–18.
Nest, ecobee and other thermostats
The manual documents Nest Learning Thermostat arrangements on pages 53–58 and ecobee arrangements on pages 59–62. Use the diagram for the exact thermostat generation and required operating modes; do not assume every thermostat supports three fan speeds. The adapter is an HVAC interface, not simply a C-wire power accessory.
Commissioning and troubleshooting
Check supply and wiring before diagnosing a control fault. The manual describes the red LED as the 24 VAC supply indicator, the green LED as the thermostat input indicator, and a blue operating indicator on some wired configurations. LED meaning and any controller test must be read with the selected solution. If the system fails to respond, stop and check the firmware, connection route and cable before replacing parts.
Pages 67–70 cover troubleshooting and site-specific EMC interference. Repeated Nest resets or missing control signals can require a supply-source review by the installer; a restart alone does not establish that the installation is corrected.
Confirm your installation
Send the complete indoor-unit model, controller model, clear terminal/PCB photos, thermostat model and required functions. Dropair can check the matching hardware, firmware and cable before you order.