This Lennox guide explains the AC interfaces documented for the Dropair Mini6 series. Select the adapter by the exact indoor unit, controller, firmware and cable; brand name alone does not confirm compatibility.

Read the original Mini6-series manual V7.3.2, 15 June 2026, pages 39–41.

Documented interfaces

LN-CN10

Adapter selection: Mini6.

CN10 PCB route using the CR-CN10-10P cable arrangement. Remove the original wired controller where the same socket is occupied.

LN-H1H2

Adapter selection: Mini6S.

Two-wire H1/H2 controller arrangement. The manual shows the adapter alongside the original communication cable and describes the connection as non-polarized.

Documented models and selection evidence

The LN-CN10 section lists 4MCDUA18TB, 4MCDUA24TB, 4MCDUA30TB, 4MCDUA36TB, 4MCDUA36TD, 4MCDUA48TD and 4MCDUA60TD. Confirm the exact indoor-unit label and available CN10 interface. The H1/H2 section does not give a separate exhaustive model list.

Important installation limits

  • The manual repeats these 4MCDUA examples in its Trane section. This is a source ambiguity, so the labels and PCB should be checked with Dropair before ordering.
  • The final LN-H1H2 terminal diagram continues onto page 41, above the Trane heading. It belongs to the Lennox solution, not the Trane CN10 route.

Original installation diagrams

These crops preserve the original diagrams, cable labels and surrounding installation notes. Read them in page order; some solutions continue across two pages. Select an image to inspect its full-resolution labels, and use the linked manual for the complete procedure.

Dropair Mini6 LN-CN10 and LN-H1H2, original manual page 40
LN-CN10 and LN-H1H2 — Mini6-series manual V7.3.2, page 40. Select the image to read the original-size labels.
Dropair Mini6 LN-H1H2 terminal diagram continuation, original manual page 41
LN-H1H2 terminal diagram continuation — Mini6-series manual V7.3.2, page 41. Select the image to read the original-size labels.

Installation checklist

  • Confirm the complete AC model, controller model, interface, adapter firmware and matching labelled cable before ordering.
  • Test the existing AC and controller before installation; record any fault codes.
  • A qualified installer must isolate and verify the supply before wiring. Mini6/Mini6S take 100–240 VAC input and provide a 24 VAC thermostat output.
  • Retain or remove the original controller only as the selected diagram requires. Follow the original diagrams for all terminal and cable assignments.
  • Use the exact thermostat wiring diagram and T568B CAT5/CAT6 connection. The adapter RJ45 port is not Ethernet and must not connect to network equipment.
  • After the installation is verified, commission supported cooling, heating, fan speeds and shutdown. Thermostat generations and configurations can differ.

General installation requirements: pages 6–18.

Thermostat setup and checks

Use the manual diagram for the exact thermostat. Nest Learning Thermostat arrangements are on pages 53–58 and ecobee arrangements on pages 59–62. Other thermostat routes are documented separately. Do not assume that every model supports three fan speeds or uses the same terminal definitions.

Confirm supply status, thermostat input and communication using the checks for the selected solution. Pages 67–70 cover troubleshooting and site-specific EMC interference. A temporary thermostat restart does not establish that an underlying wiring or supply issue has been corrected.

Confirm the correct configuration

Send Dropair the full indoor-unit model, original controller model, thermostat model, PCB/terminal photographs, wiring diagram and required functions. If the manual does not name your exact model, request a compatibility check before selecting the adapter.