This Gree guide explains the AC interfaces documented for the Dropair Mini6 series. Select the adapter by the exact indoor unit, controller, firmware and cable; brand name alone does not confirm compatibility.
Read the original Mini6-series manual V7.3.2, 15 June 2026, pages 46–47.
Documented interfaces
GR-H1H2
Adapter selection: Mini6S.
Indoor unit with the documented two-wire H1/H2 remote controller. The adapter connects alongside the original communication cable. This connection is described as non-polarized.
Documented models and selection evidence
The Gree section documents an interface condition, not a complete list of indoor-unit model numbers. Provide the full model, controller and H1/H2 terminal photos for confirmation.
Important installation limits
- Page 18 explicitly excludes Gree from the standard original-controller automatic-off communication test. Use the required thermostat-based test rather than diagnosing a fault from the generic test.
- The H1/H2 controller interface must not be inferred from the presence of any two wires. Verify their labels, function and the matching adapter firmware.
Original installation diagrams
These crops preserve the original diagrams, cable labels and surrounding installation notes. Read them in page order; some solutions continue across two pages. Select an image to inspect its full-resolution labels, and use the linked manual for the complete procedure.

Installation checklist
- Confirm the complete AC model, controller model, interface, adapter firmware and matching labelled cable before ordering.
- Test the existing AC and controller before installation; record any fault codes.
- A qualified installer must isolate and verify the supply before wiring. Mini6/Mini6S take 100–240 VAC input and provide a 24 VAC thermostat output.
- Retain or remove the original controller only as the selected diagram requires. Follow the original diagrams for all terminal and cable assignments.
- Use the exact thermostat wiring diagram and T568B CAT5/CAT6 connection. The adapter RJ45 port is not Ethernet and must not connect to network equipment.
- After the installation is verified, commission supported cooling, heating, fan speeds and shutdown. Thermostat generations and configurations can differ.
General installation requirements: pages 6–18.
Thermostat setup and checks
Use the manual diagram for the exact thermostat. Nest Learning Thermostat arrangements are on pages 53–58 and ecobee arrangements on pages 59–62. Other thermostat routes are documented separately. Do not assume that every model supports three fan speeds or uses the same terminal definitions.
Confirm supply status, thermostat input and communication using the checks for the selected solution. Pages 67–70 cover troubleshooting and site-specific EMC interference. A temporary thermostat restart does not establish that an underlying wiring or supply issue has been corrected.
Confirm the correct configuration
Send Dropair the full indoor-unit model, original controller model, thermostat model, PCB/terminal photographs, wiring diagram and required functions. If the manual does not name your exact model, request a compatibility check before selecting the adapter.
Request a compatibility check · Mini6 product details · Mini6S product details · All Mini6 brand guides