Use this guide to identify the documented Dropair Mini6-series connection routes for Daikin air conditioning. Compatibility depends on the exact indoor unit, control interface, adapter hardware, firmware and cable—not the brand name alone.
Source: Mini6 / Mini6S Installation and Service Manual V7.3.2, 15 June 2026, pages 19–24.
Choose the documented connection route
DK-P1P2
Adapter: Mini6S. Installation condition: P1/P2 two-wire control interface, with or without the original wired controller.
Confirm the P1/P2 terminals on the exact indoor unit. The P1/P2 connection is non-polarized in this documented solution.
DK-S21 / DK-S403
Adapter: Mini6S. Installation condition: S21 or S403 socket on the indoor PCB.
S21 examples include CTX, FDX, FVX, FFQ and FTX series. The manual names BRC944C1 as an example controller. Where the adapter occupies the controller socket, follow the specified controller-removal arrangement.
DK-CN2
Adapter: Mini6. Installation condition: Four-pin blue remote-controller connection.
Examples: FDMRN, FDM, FDYM, FDB and FDYB series; BRC51A, BRC51B, BRC51C and BRC51D66 controllers. Use the supplied cable; the manual distinguishes gray and black cable wire colours.
DK-CNWIR
Adapter: Mini6S. Installation condition: CN-WIR rooftop packaged arrangement.
Section 4.1.7 names UATQ-CGXY1, UATQ60C, UATQ90C, UATQ120C, UATQ150C, UATQ180C, UATQ240C and UATQ300C; BRC51D65 is a controller example. A/B polarity must be respected.
DK-INA
Adapter: Confirm configuration. Installation condition: CN10 or CN18 socket on the indoor PCB.
This India-specific arrangement uses the socket previously occupied by the wired controller. Confirm the hardware and cable with Dropair before selection.
Model and installation limits
- The compatibility table on page 7 says QATQ, while the rooftop section on page 23 says UATQ. Use the complete equipment label and request confirmation rather than treating those identifiers as interchangeable.
- The CN2 and rooftop sections describe limited controller-state synchronization. Assess actual indoor-unit operation rather than relying only on the original controller display.
- Those sections also describe a compressor-protection delay of up to about four minutes. Do not repeatedly cycle power to try to bypass the delay.
The examples above identify the model or interface families explicitly mentioned in this manual. A missing model number is not confirmation of either support or incompatibility. Request a review for your exact installation.
Original installation diagrams
These crops preserve the original diagrams, cable labels and surrounding installation notes. Read them in page order; some solutions continue across two pages. Select an image to inspect its full-resolution labels, and use the linked manual for the complete procedure.






Installation workflow
- Check the complete indoor-unit model and control interface, then verify the adapter label, firmware and supplied cable against the chosen solution.
- Test the air conditioner with its original controller before making changes. Record any existing faults.
- A qualified installer must isolate and verify the electrical supply before wiring. Mini6 / Mini6S have a 100–240 VAC input; their thermostat output is 24 VAC. These are not interchangeable connections.
- Follow the exact brand diagram and retain the original controller unless that diagram specifically requires removal. Do not translate one brand’s terminal assignments to another.
- Connect the supported thermostat using the model-specific thermostat diagram and correctly terminated T568B CAT5/CAT6 cable. The RJ45 socket is not Ethernet and must never connect to a router or switch.
- After wiring checks, commission the configured heating/cooling and fan functions supported by the actual equipment. Thermostat models have different terminal definitions and fan-speed capabilities.
Source: Mini6 / Mini6S Installation and Service Manual V7.3.2, 15 June 2026, pages 6–18.
Nest, ecobee and other thermostats
The manual documents Nest Learning Thermostat arrangements on pages 53–58 and ecobee arrangements on pages 59–62. Use the diagram for the exact thermostat generation and required operating modes; do not assume every thermostat supports three fan speeds. The adapter is an HVAC interface, not simply a C-wire power accessory.
Commissioning and troubleshooting
Check supply and wiring before diagnosing a control fault. The manual describes the red LED as the 24 VAC supply indicator, the green LED as the thermostat input indicator, and a blue operating indicator on some wired configurations. LED meaning and any controller test must be read with the selected solution. If the system fails to respond, stop and check the firmware, connection route and cable before replacing parts.
Pages 67–70 cover troubleshooting and site-specific EMC interference. Repeated Nest resets or missing control signals can require a supply-source review by the installer; a restart alone does not establish that the installation is corrected.
Confirm your installation
Send the complete indoor-unit model, controller model, clear terminal/PCB photos, thermostat model and required functions. Dropair can check the matching hardware, firmware and cable before you order.
Request a compatibility check · Mini6 details · Mini6S details · Manual library